BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//kigkonsult.se//NONSGML kigkonsult.se iCalcreator 2.41.92//
CALSCALE:GREGORIAN
UID:62396265-3831-4131-a338-653230646365
BEGIN:VTIMEZONE
TZID:UTC
END:VTIMEZONE
BEGIN:VEVENT
UID:35396666-3139-4166-b039-386566346461
DTSTAMP:20260930T182630Z
CLASS:PUBLIC
DESCRIPTION:The PANalytical Empyrean diffractometer is an excellent choice 
 for X-ray powder/polycrystalline diffraction measurements with low backgro
 und. The default mode of this instrument is in Bragg-Brentano parafocusing
  geometry with CuKa1\,Ka2 doublet radiation. Samples can be loaded into a 
 45-position sample changer to input into the reflection-transmission spinn
 er stage. The instrument has linear position sensitive detector (Pixcel 1D
 \, max count rate: 6.5 x 10^9 cps) which permits rapid data collection up 
 to 255 times faster than with a traditional point detector.\n\nThe basic i
 nstrument training session will focus on the collection of powder diffract
 ion data using the Bragg Brentano High Definition (BBHD) flat mirror optic
 \, 45-position sample changer\, reflection transmission spinner (in reflec
 tion geometry) and the Pixcel 1D detector.Â  This configuration is best su
 ited for high-speed high-resolution data collection from powders and polyc
 rystalline thin films.\n\nAccessories include a Anton Paar CHC+ Cryo-Humid
 ity stage. After you have completed this training\, you can request indivi
 dual training on the humidity stage available with this instrument. The sa
 mple temperature range is from â180 Â°C to +400 Â°C with     liquid nitr
 ogen cooling\, and from â5 Â°C to +400 Â°C with compressed air     cooli
 ng. The sample relative humidity range is 5 to 95 % RH at 10 Â°C to 60 Â°C
  and 5 to 70% RH at 80 Â°.\nÂ \nUsers of this instrument should also stron
 gly consider taking a data analysis course to suit their needs\, such as t
 he line profile fitting course for crystallite size and microstrain analys
 is\, the Rietveld refinement series for quantitative phase analysis and un
 it cell analysis\, or the Introduction to High Score Plus for qualitative 
 phase identification and database search techniques.\nThe basic instrument
  training session will focus on the collection of powder diffraction data 
 using the Bragg Brentano High Definition (BBHD) flat mirror optic\, 45-pos
 ition sample changer\, reflection transmission spinner (in reflection geom
 etry) and the Pixcel 1D detector.Â  This configuration is best suited for 
 high-speed high-resolution data collection from powders and polycrystallin
 e thin films.\n\nAccessories include a Anton Paar CHC+ Cryo-Humidity stage
 . After you have completed this training\, you can request individual trai
 ning on the humidity stage available with this instrument. The sample temp
 erature range is from â180 Â°C to +400 Â°C with     liquid nitrogen cool
 ing\, and from â5 Â°C to +400 Â°C with compressed air     cooling. The s
 ample relative humidity range is 5 to 95 % RH at 10 Â°C to 60 Â°C and 5 to
  70% RH at 80 Â°.\nÂ \nUsers of this instrument should also strongly consi
 der taking a data analysis course to suit their needs\, such as the line p
 rofile fitting course for crystallite size and microstrain analysis\, the 
 Rietveld refinement series for quantitative phase analysis and unit cell a
 nalysis\, or the Introduction to High Score Plus for qualitative phase ide
 ntification and database search techniques.\nSAXS - small angle X-ray scat
 tering\nWAXS - wide angle X-ray scattering\nGISAXS - grazing incidence sma
 ll angle X-ray scattering
DTSTART:20240529T170000Z
DTEND:20240529T183000Z
LOCATION:13-4027 (Campus Map: https://whereis.mit.edu/ )
SEQUENCE:1
SUMMARY:PANalytical Empyrean XRPD Instrument Specific Training- May 29
TRANSP:OPAQUE
END:VEVENT
END:VCALENDAR
